E. 02 | CPU Circuit board failure | It cannot be dealt with locally. |
---|
E. 03 |
---|
E. 04 |
---|
E. 05 | Internal error in layer information management |
---|
E. 09 | Communication error when starting the controller |
---|
E. 10-1 | Incompatibility of motor A capacity and controller | Use the correct motor capacity and controller. |
---|
E. 10-2 | Incompatibility of motor B capacity and controller |
---|
E. 10-3 | The press rotation sensor has not been Initial setting | Write the angle and rotation direction from the initial settings. |
---|
E. 11 | Controller setting error | It cannot be dealt with locally. |
---|
E. 12 |
---|
E. 13 | Mismatch between main body and controller | Use a controller that matches the main unit. |
---|
E. 14 | Connected a device not supported by the software | Remove the added optional equipment. Request a software version update. |
---|
E. 15 | Abnormal voltage in power supply circuit | It cannot be dealt with locally. |
---|
E. 16-1 | Incompatibility between motor A and controller | Use the correct motor/controller. |
---|
E. 16-2 | Incompatibility between motor A and controller |
---|
E. 17 | Abnormal voltage in power supply circuit | It cannot be dealt with locally. |
---|
E. 20-7 | Power supply board circuit abnormality |
---|
E. 20-8 |
---|
E. 21-7 |
---|
E. 21-8 |
---|
E. 22 | Feed brake circuit failure |
---|
E. 23 |
---|
E. 24 | Abnormal operation of feed brake | Check for abnormal operation of the feed brake and damage to the feed brake cable. Re-insert the BRK connector. |
---|
E. 26 | Material fall prevention mechanism does not open | Is the fall prevention mechanism working? Does the stopper move by hand when the power is turned off? |
---|
E. 27 | Back stopper abnormal | Is there anything caught in the fall prevention mechanism? |
---|
E. 28 | The feed brake mechanism does not open | It cannot be dealt with locally. |
---|
E. 29 | Feed brake mechanism does not close |
---|
E. 30 | Display board communication error |
---|
E. 31 | Communication error with optional equipment
*The number changes depending on the connection position of the device Seen from the connector cover side, 31, 32, 33, 34 from left to right | Check cable for damage. Re-insert the Options connector. |
---|
E. 32 |
---|
E. 33 |
---|
E. 34 |
---|
E. 39 | Control error of optional equipment. | It cannot be dealt with locally. |
---|
E. 42 | High voltage detection | Check the power supply voltage. Reduce acceleration (press speed). Review the material loop. Reduce material weight. |
---|
E. 43 |
---|
E. 45 | Controller power supply voltage abnormality | It cannot be dealt with locally. |
---|
E. 46 | Controller internal voltage abnormality. |
---|
E. 47 |
---|
E. 48 | Internal abnormality of controller. |
---|
E. 49 | Controller power failure. |
---|
E. 50-1 | Motor A communication error | Check the motor A cable for damage. Re-insert the MT-A connector. |
---|
E. 50-2 | Motor B communication error | Check the motor B cable for damage. Re-insert the MT-B connector. |
---|
E. 50-3 | Press rotation sensor connection error | Check the rotation sensor cable for damage. Re-insert the P-EN connector. |
---|
E. 50-9 | MP6 internal abnormality | It cannot be dealt with locally. |
---|
E. 51 | Connection error between motors A and B | Re-insert the MT-A and MT-B connectors. |
---|
E. 52-1 | No need to connect motor A | Unplug the MT-A connector. |
---|
E. 52-2 | No need to connect motor B | Unplug the MT-B connector. |
---|
E. 52-3 | No rotation sensor connection required | Wrong model / cable connection. |
---|
E. 53-1 | Incompatibility between motor A and controller | Use the correct motor/controller. |
---|
E. 53-2 | Incompatibility between motor B and controller |
---|
E. 58-3 | Press rotation sensor communication error | Check the rotation sensor cable for damage. ・Re-insert the P-EN connector. |
---|
E. 59 | Controller internal communication error | It cannot be dealt with locally. |
---|
E. 60-1 | Motor A overload /heating abnormality | Reduce acceleration (press speed). Review the material loop. Is the release timing off? Isn't the material still under load due to hitting it against the mold? Reducing the weight of materials. |
---|
E. 60-2 | Motor B overload /heating abnormality |
---|
E. 61-1 | Abnormal operation of motor A. | Check the motor A cable for damage. Re-insert the MT-A connector. |
---|
E. 61-2 | Abnormal operation of motor B. | Check the motor B cable for damage. Re-insert the MT-B connector. |
---|
E. 62-1 | Motor A control error | It cannot be dealt with locally. |
---|
E. 62-2 | Motor B control error |
---|
E. 63-1 | Discrepancies in the positional relationship of multiple motors. (or voltage abnormality in the power supply circuit) |
---|
E. 68 | Origin detection error | Reinsert the MT-A connector. Can you manually move the feed mechanism with the power turned off? Apply lubricant to the movable shaft. |
---|
E. 70-2 | Overload /heating abnormality of plate thickness motor | It cannot be dealt with locally. |
---|
E. 70-4 | Electromagnet control abnormality, electromagnet failure |
---|
E. 70-5 |
---|
E. 71-2 | Abnormal operation of plate thickness motor | Check the motor cable for plate thickness adjustment for damage. Re-insert the MT-B connector. |
---|
E. 71-4 | Electromagnet control abnormality, electromagnet failure | It cannot be dealt with locally. |
---|
E. 71-5 |
---|
E. 72-2 | Plate thickness motor control error |
---|
E. 75-2 | Abnormality of plate thickness adjustment mechanism | Checking the plate thickness adjustment mechanism |
---|
E. 77-4 | Abnormal operation of electromagnet. | Check the solenoid cable for damage. Re-insert the P-SOL connector. |
---|
E. 77-5 |
---|
E. 78 | Electromagnet control abnormality | It cannot be dealt with locally. |
---|
E. 84-1 | Controller internal over fever | Allow enough time for the controller to cool down. Use in an operating environment below 40℃. Reducing material weight. |
---|
E. 84-2 |
---|
E. 85-1 | 【A/A-A】Fan abnormality inside the controller. 【T/G/H】Fan abnormality at the bottom of the controller | 【A/A-A】It cannot be dealt with locally. 【T/G/H】 Is the fan spinning? Re-insert the fan connector. Replace the fan. |
---|
E. 85-2 | Fan abnormality at the bottom of the controller | Is the fan spinning? Re-insert the fan connector. Replace the fan. |
---|
E. 85-3 |
---|
E. 85-4 | Electromagnet fan abnormality | Is the fan spinning? Reinsert the FN /IO-B connector. Replace the fan. |
---|
E. 85-5 |
---|
E. 85-6 | Motor fan error | Is the fan spinning? Reinsert the FN /IO-A connector. Replace the fan. |
---|
E. 85-7 |
---|
E. 99-9 | Internal abnormality of controller | It cannot be dealt with locally. |
---|
| | |
---|
AC_OFF | Detects power OFF Detects momentary power outage | The display is normal when the power switch is OFF. Turn off the power and turn it on again. Use a power supply with stable voltage. |
---|
Lo_PS . |
---|
| | |
---|
E. [4桁] | Internal abnormality of controller. | It cannot be dealt with locally. |
---|